A: All of the Zopec EXPLORE batteries were designed for medical back-up power. You can have the power bank be plugged in a wall outlet and power the CPAP at the same time. The CPAP will run. The battery will stay 100% (FF) charged. They have bypass built-in so this will not hurt the battery life. When the power bank is plugged in the wall outlet, the CPAP machine draws power from the wall outlet and bypass the power bank. When the power outage occurs, the CPAP machine will start to run by the power bank.
-
A: Yes. All of the Zopec EXPLORE batteries have our AutoSwitch technology built-in. In an event of power outage, it will automatically switch to power bank power and you don't have to wake up to switch. It works very nicely. You can try it and see it works well. You will not even know when an power outage occurs. You can test it. Just have everything plugged in and use the CPAP then unplug from the wall.
-
A: Yes for Zopec EXPLORE Mini, 4000, and 5500 models. You can bring them in your carry-on luggage but you can NOT put them in check-in luggage. FAA does not allow any lithium ion batteries and power banks in check-in luggage. NOTE: You can NOT bring Zopec EXPLORE 8000 for air travel.
The maximum capacity limit for lithium ion batteries and power banks for carry-on luggage is 160 Watt Hours (Wh). You can NOT bring Zopec EXPLORE 8000 (288 Wh) for air travel because its capacity exceeds the limit.
For battery or power bank capacity of 100 Wh and under, you don't need to ask airline for approval and there are no quantity limit to bring on the airplane. This applies to Model EXPLORE Mini (97 Wh).
For batteries or power bank capacity of 101 - 160 Wh, you need to ask airline for approval prior to travel and there is a quantity limit of 2. This applies to Models EXPLORE 4000 (120 Wh) and EXPLORE 5500 (160 Wh) batteries We have contacted all major commercial airlines and have always gotten the approval. Also, our sales team travel by air every week and they always carry all 3 batteries on the airplane with no issues.
-
The run time depends on the CPAP machine, power bank model, pressure setting, and humidifier setting. For Model EXPLORE 8000, it will run 12 hours at pressure of 10 and humidifier at mid-setting (4) for ResMed AirSense10. If you use higher setting of pressure and humidifier, please click on "Run Time Chart" at the top menu bar and you will be able to find the approximate run time.
-
A: Yes, we have many customers using our power banks in the RV. That is exactly what you would do. During the day time, the generator is on and you would recharge the power bank with the wall outlet in the RV. At night, you would run the CPAP with our power bank. Depending on your machine setting and which power bank you get, you may get several nights in a single charge.
-
A It is best to just let it sit. When you need it, charge it overnight to full charge and the power bank will reset itself. The battery will be ready to go for camping.
Here is some more details for reference. All lithium ion batteries or power banks will deplete over a few months due to leakage current. It will just need to recharged overnight and the power bank will reset itself. This initial charge is slow to reset the power bank. After that, it will charge faster. Our batteries have the premium Panasonic cells inside and sitting does not hurt this our power banks. This is not the case for many other brand batteries with less quality cells.
When you turn it back on in a few months, the indicator may show around 40% - 65% charged but it is actually depleted. Just recharge overnight to full and the battery will reset itself. Depending the model, it might about 5-6 hours before the charge indicator is correct. This is only the case that if it sits for a long time and battery depleted by leakage current. Otherwise, the charge indicator will always be correct if used frequently.
-
A: The universal power supply comes with every power bank. Each power bank purchase includes the Power Bank, Universal Power Supply, Protective Microfiber Bag, User Manual and Nice White Storage Box. Some CPAP batteries don't include universal power supply and needs to be purchased separately. We do include it.
-
A: You don't need a special cord or plug with our power banks. It comes with 3 Prong 110V Outlets just like home. It works with all machines without adapters or special cord. You simply plug in like a home wall outlet and it works. We have simplified everything for customers.
-
A: When you have heated humidifier and heated tube turned on, you will lose about 80% of the running time. That is because it takes a lot of power to evaporate water and heat the 6 feet heated hose.
Below are some examples for Philips and ResMed machines with Model Zopec EXPLORE 5500:
Philips Respironics DreamStation at Pressure of 10 cm H2O:
- 21 hours WITHOUT heated humidifier and heated tube
- 6 hours with heated humidifier alone (mid setting)
- 4 hours with heated humidifier and heated tube (mid setting)
ResMed AirSense10 at pressure 10 cm H2O:
- 16 hours without heated humidifier and heated tube
- 8 hours with heated humidifier alone (mid setting)
- 4 hours with heated humidifier and heated tube (temp 78F)
-
A: Yes. At home, most people will use the heated humidifier and/or heated tube. We had to design in enough power so we have effective backup power solution. Our EXPLORE 8000 and in some cases EXPLORE 5500 power banks have enough capacity to run with mid setting heated humidifier and provide at least 8 hours of sleep. If you also want to run heated tube or maximum setting on heated humidifier, then you can link the power banks in series to get any power you need to get 8 or more hours of sleep. Please check our machine run time chart to find out how many hours it will last for your machine and your settings. If you just have the humidifier on and not heated tube, it will save a lot of power. To have longer machine running time, we recommend not to turn on the heated tube unless you have "rain out" or condensation of water in the CPAP hose. In the United States, you would not need the heated tube for most areas.
-
A: For ResMed AirSense10, the heated humidifier can not be detached so you have to use change the settings. To turn off, go to MyOptions and turn ClimateControl to Manual Mode. Next, Turn both Humidifier Level and Tube Temperature to OFF.
For most machines including Philips Respironics DreamStation, ResMed S9, and DeVilbiss IntelliPap, you can just detach the humidifier from the CPAP unit and plug the CPAP hose directly to the CPAP Unit. That ensures the heated humidifier and the heated hose are turned off.
Hospital FAQs
-
Description text goes here
-
Description text goes here
-
Description text goes here
Warranty & Technical Support
-
Zopec’s limited warranty is available to the initial consumer and is not transferable. Should covered products fail as a result of normal use, Zopec Medical will replace or repair at it’s discretion the failed parts, components or product in it’s entirety. Zopec Medical warrants that the device will be free from defects and will perform in accordance with the product specifications for the periods listed here to for in this statement.
-
-Damage or defect caused by improper use, neglect, device modification or abuse of the product
-Use of ozone generating devices intended to sanitize product, exposure to ozone or other gases
-Repairs provided by entities not expressly approved by Zopec Medical
-Damage caused by smoke, including cigarette, cigar and pipe smoke
-Damage, infestation or contamination of pests, insects and rodents
This warranty replaces all other expressed or implied warranties, including manufacturer’s warranties. Zopec Medical will not be responsible and held harmless from incidental or consequential damages claimed to have resulted from the sale, installation implementation or use of any Zopec Medical product. Zopec Medical disclaims all liability for economic loss, loss of profits, overhead or consequential damages which may be claimed to arise from any sale or use of this product. Some states do not allow the exclusion or limitation of incidental or consequential damages, check local laws to specify if this exclusion applies to you.
-
-Resvent iBreeze Auto CPAP
-Resvent iBreeze Auto BiPAP/AVAPS 30STA
-Beyond ResPlus Auto CPAP
-Beyond ResPlus BiPap/AVAPS
-Apex Medical XT Auto CPAP
-Hypnus 7 Auto BiPAP
-
-All non-invasive ventilation humidifiers
-Zopec EXPLORE Travel CPAP/BiPAP Battery
-Zopec EXPLORE Backup UPS CPAP/BiPAP Battery
-Zopec VOYAGE Universal Battery
-Zopec TRANSPORT Battery and UPS Backups
-Zopec PHOTONS Solar Charger
-
-Disposable filters
-Reusable filters
-Water chambers
-Power cords
-Carrying cases and bags
-Chargers (car and wall outlet)
All Technical Support Issues can be addressed at RMA@Zopec.com, your issue will be assigned to the proper department head for the product in question. Please include serial numbers and contact information on each email for tracking purposes.